Ah, the power of a thousand pores.
Sometimes, that is just what a porosity/inclusion analysis (PIA) gives you. But nobody wants data on a thousand pores; normally, we just need to inspect the largest ten, or the most voluminous five, to make sure the part will run smoothly.
Let's take a look at our strut mount: the component that attaches the suspension strut to the vehicle. For such a small part, it goes through a lot of wear and tear, cushioning the ups and downs of a bumpy ride. We want to make sure it lasts a long time; however, we also want to make sure reading the report doesn't. The question is, how can we get all the info we need in a (and user-friendly) nutshell?
The answer is simple: rule-based annotations!
Let's start by running a quick PIA. In some cases, we need all the pores—big and small—like when we need to determine and tolerate the overall defect volume ratio of the part.
So many pores, so little time. A quick PIA shows over 2000 pores smaller than 0.1 mm³
Of course, we have just taken into consideration hundreds of tiny pores, but it may be of interest to take a look at the biggest of them all. But how can we get the correct defect volume ratio (which is calculated based on overall porosity) but only including the largest pores in one bite-sized report? And more importantly, how do we set a limit to the number of results?
Best of Both Worlds
Rules allow us to set a threshold for rule-based annotations. Using one of the properties, you can generate annotations for results larger or smaller than this threshold. For example, creating annotations for pores larger than 2 mm³ results in 14 annotated pores, which is immediately indicated in the dialog.
Here's how the report looks: clean, crisp, and to-the-point.
Using rule-based annotations reduced the size of the report to only 18 pages—imagine if we had included every pore!
Let's try out other analyses. Since our strut mount comes with a CAD file, we can run a nominal/actual comparison (NAC) to calculate the maximum deviations in the physical part. In this case, let's create a rule for 5 maximum positive—and 5 maximum negative—deviations.
Rinse and repeat…
Different angles of the strut mount, so we can clearly see the maximum positive and maximum negative deviations
And there you have it! All the info you need at a glance.
Rule-based annotations are handy for compiling quick, bite-sized information. Perfect for a Friday afternoon.
Did You Know? Arrange, Minimize, and Maximize Annotations
Sometimes, we can actually end up with too many annotations. They clutter the workspace and overlap each other. There is an easy way to clean up the mess, though.
Simply right-click in a window, click "annotations," and arrange. To minimize all of them, just click "minimize." Now it is much better!
Ready to Learn More?
Users of VGSTUDIO MAX can find out more about porosity/inclusion analyses, nominal/actual comparisons, and creating annotations in the tutorials included in the software.
Got a Story?
If you have a VG Story to tell, let us know! Contact our Storyteller Team at: storytellers@volumegraphics.com. We look forward to hearing from you.